Pump Chambers

Definition: a part of a lamp-pumped solid-state laser, containing a laser rod, one or more lamps, reflectors, a cooling arrangement and possibly other parts

German: Pumpkammern

Categories: lasers, photonic devices

How to cite the article; suggest additional literature

A pump chamber is an assembly around the laser rod (or slab) within the laser resonator of a lamp-pumped laser or within a laser amplifier setup. Besides the laser rod, it typically contains the following:

lamp-pumped rod
Figure 1: Lamp-pumped laser rod in a water-cooled pump chamber with reflective walls.

In case of a slab laser, one often uses one lamp of each side of the slab. instead of a filter tube, one can use flat filter windows between the slab and the lamps.

For essentially all lamp-pumped lasers, the technique of side pumping is used, since the diffuse nature of the lamp emission is not suitable for end pumping.

For a simple laser, the pump chamber needs to be supplemented only with two laser mirrors for forming a laser resonator. Additional optical components may be placed within the laser resonator – for example, additional mirrors, a Brewster plate for enforcing linear polarization, and a Q switch for short pulse operation.

There are also laser pump modules containing laser diodes instead of lamps; those are usually not called laser pump chambers, since they do not require a reflecting chamber for directing the pump light. However, the term sometimes appears in the context of slab lasers and thin-disk lasers, where multiple pump reflections are used.

Further Details of Laser Pump Chambers

Laser Gain Media

Different laser media are used in laser pump chambers. A common choice is Nd:YAG, typically for emission at 1064 nm, but one also various other types of laser crystals for obtaining other output wavelengths (e.g. Nd:YLF for 1047 nm, Er:YAG for 1.6 μm or 2.94 μm or Ho:YAG for 2.1 μm) and erbium- or neodymium-doped glass rods for broadband high energy amplifiers.

Rod Dimensions and Doping Concentration

A thicker and/or more highly doped laser rod can of course more efficiently absorb the pump radiation. On the other hand, efficient energy extraction combined with high laser beam quality is tentatively more difficult with thicker rods, and high doping concentrations increase the tendency for power losses through upconversion phenomena, particularly in pulsed lasers. The optimum choice of rod diameter results from a compromise between different aspects which depends on the detailed circumstances. Typically, rods with diameters of the order of 5 to 10 mm and moderate doping concentration are used.

Long pump chambers for the use of correspondingly long rods and lamps are suitable for higher laser powers or energies. However, challenges related to thermal lensing, for example, are getting stronger at high power levels. Typically, the rod length is between 50 and 200 mm.

Pump chambers often allow the use of rods which are somewhat longer than the required minimum length. The outer parts of the laser rod may then remain unpumped, which however does not significantly reduce the laser efficiency in case of a four-level laser medium such as Nd:YAG, because those do not exhibit reabsorption of laser light. The advantages of using a somewhat longer rod can be that it is easier to insert, and that there is some reserve for later shortening e.g. if a damaged end face needs to be polished again.

Designs with Multiple Lamps or Rods

The use of multiple lamps in a pump chamber allows not only the generation of higher pulse energies, but can also lead to a more symmetric distribution of pump light. Therefore, dual-lamp designs with lamps on opposite sides of the rod are common.

In some cases, a pump chamber contains multiple laser rods. (The laser light may subsequently be sent through different rods.) Using multi-rod chambers can provide increased output power combined with an increased conversion efficiency, since the absorption efficiency can be enhanced.

Materials for Reflectors

Different materials can be used for pump light reflectors. Metals like gold and silver (used as thin coatings, e.g. gold on brass or silver on nickel-plated aluminum) provide high reflectivities over wide spectral ranges. The specular reflection of metal surfaces makes it necessary to optimize the geometry for good power transfer efficiency and sufficient uniformity of the pump intensity. (Non-uniform pump profiles can lead to increased problems e.g. with thermal lensing and concerning beam pointing fluctuations.)

There are also materials providing diffuse scattering rather than specular reflection, for example white ceramics, certain polymer materials or a packed powder (e.g. barium sulfate). Diffuse scattering can provide a more uniform pump intensity distribution in the rod, but is tentatively less efficient in terms of power transfer, because it may take multiple scattering events for light to get to the laser rod. On the other hand, ceramic diffuse reflectors are quite durable, while metallic surfaces may tarnish over the time (particularly when exposed to cooling water, which may not be perfectly clean) and may then have to be repolished.

Particularly when using a laser rod with low absorption (e.g. due to a small diameter), low absorption of the scattering materials is important for a high power conversion efficiency. The geometric shape of the reflecting (actually scattering) surface is less important; one can use, for example, a ceramic with cuboid or oval shape of the cavity containing rod and lamps. Often, one uses close-coupled configurations, i.e., with a small distance between lamp and laser rod.

Filter Glass

As mentioned above, the filter glass tube may be used for protecting the laser rod against detrimental spectral components of the lamp light. Particularly, ultraviolet light is often removed which could cause crystal defects and thus a degrading optical transparency (solarization). Also, some spectral components are not useful for the laser process and only lead to additional heating of the rod, so that their removal in the filter glass can be beneficial. In some cases, the absorbed light is even converted to fluorescent light at longer wavelengths which is useful for the laser process. For Nd:YAG lasers, silicate filter glasses doped with cerium (Ce) and samarium (Sm) are common.

Water Flow

The flow of the coolant (typically water) must obviously be sufficient to remove the excess heat while avoiding excessive temperatures. It can also be advantageous to optimize the coolant flow such that the temperature profile around the laser rod is quite uniform, so that astigmatic thermal lensing and problems with beam pointing fluctuations are minimized.

Most pump chambers are so-called wet chambers, where the lamp(s) and rod(s) are in direct contact with the cooling water. However, there are also dry designs, where those parts are separated from the cooling water, usually by glass tubes (flow tubes). The latter approach may have practical advantages, but particularly the cooling of the laser rod is then less effective.

Depending on details of the construction (e.g. used materials), there may be different requirements on the purity of the cooling water. Operating a pump chamber outside such specifications for longer while may lead to serious degradation or defects, e.g. due to corrosion.

An important aspect of the quality of the construction of a pump chamber is the safe avoidance of cooling water leaks, which otherwise could lead to electrical problems (even hazards) and/or the contamination of optical surfaces.

OEM Pump Chambers

Pump chambers may be sold with or without the corresponding laser rod and lamps. They are often used as OEM parts, so that a manufacturer can produce lamp-pumped lasers without fabricating pump chambers himself.

Suppliers

The RP Photonics Buyer's Guide contains 2 suppliers for pump chambers. Among them:

See also: lamp-pumped lasers, laser heads, side pumping, pump absorption, solid-state lasers
and other articles in the categories lasers, photonic devices

How do you rate this article?

Click here to send us your feedback!

Your general impression: don't know poor satisfactory good excellent
Technical quality: don't know poor satisfactory good excellent
Usefulness: don't know poor satisfactory good excellent
Readability: don't know poor satisfactory good excellent
Comments:

Found any errors? Suggestions for improvements? Do you know a better web page on this topic?

Spam protection: (enter the value of 5 + 8 in this field!)

If you want a response, you may leave your e-mail address in the comments field, or directly send an e-mail.

If you enter any personal data, this implies that you agree with storing it; we will use it only for the purpose of improving our website and possibly giving you a response; see also our declaration of data privacy.

If you like our website, you may also want to get our newsletters!

If you like this article, share it with your friends and colleagues, e.g. via social media:

arrow